A DC Parts is a distributor of new and refurbished HPE equipment and accessories. Our technology experts can help you select and configure the right HPE blade solution for your specific data needs. Like all of our equipment, HPE blades are fully tested, you can count on worry-free service for years to come. And, should the need arise, our team of certified engineers is on hand to provide support for any issues you may have. If you would like to speak with a representative about HPE equipment offerings, please contact contact us.

HP BladeSystem Platinum c7000 Enclosure

The BladeSystem c7000 enclosure provides all the power, cooling and I/O infrastructure needed to support modular servers, interconnect and storage components today and for years to come.

BladeSystem c7000 Blade Enclosure Generations

What's New in the HP BladeSystem c7000 Enclosure

  • RoHS Compliance
  • 7Tb/s medium plane (40% increase), improved signal integrity; he adds:
  • 16Gb FC
  • 4xFDR IB (> 1 port / server)
  • Single-phase smart input module
  • Location Discovery Services
  • 2650W Platinum Power Supply Options
  • High Voltage Power Solution Options

The enclosure is 10U tall and holds up to 16 servers and/or storage blades, plus optional redundant networking and storage interconnect modules. Includes a shared high-speed 7,1 Tbps NonStop mid-range plan for unique blade server connectivity to shared storage and network. Power is supplied through a pooled power back panel and power input flexibility is provided with single-phase AC input, three-phase AC input, -48V DC input, and high voltage DC input options.

HPE BladeSystem Platinum c7000 Enclosure – front view

 

Each c7000 cabinet is built with the following functions:

  • Up to 16 half-height server blades, 8 full-height server blades, and/or 8 expansion blades per enclosure (not to exceed 16 blades total).
  • Up to 4 redundant interconnect I/O fabrics (Ethernet, Fiber Channel, InfiniBand, iSCSI, SAS, etc.) supported simultaneously within the enclosure. • Choice of high-line single-phase AC, high-line three-phase AC, high-voltage single-phase AC, -48 VDC, or high-voltage DC power options for flexibility in connecting to data center power.
  • HPE Thermal Logic technology to minimize power consumption and reduce cooling.
  • At least four HPE Active Cool 200 hot-plug fans. For additional capacity, redundancy and improved power consumption and acoustics, Active Cool 200 Fan kits can be added for a maximum of 10 fans.
  • Redundant hot-plug cooling, redundant hot-plug power supplies, redundant connections, redundant interconnect modules, and optional redundant BladeSystem Onboard Administrator management module.

Extending the foundation for converged infrastructure

  • The HPE BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, network and power management into a single solution that can be managed as a unified environment.
  • With demanding workloads, increased power supply power and mid-range bandwidth aligned with intelligent infrastructure technologies such as Platinum Power Supplies, Smart Power Module, and location discovery services have enhanced the foundation for converged infrastructure.
  • HPE OneView combines server, storage and networking with control of your data center environment into a single integrated management platform designed to provide lifecycle management for the complete converged infrastructure.
  • With Onboard Administrator, iLO Remote Management, and HPE OneView, you can manage your servers and take full control, regardless of the state of the server's operating system.

 

BLc7000 Blade Enclosure Platinum - Rear View

Características do produto

Feature
Overview
Tasks
  • Up to 16 half-height server blades, 8 full-height server blades, and/or 8 expansion blades per enclosure (not to exceed 16 blades total).

  • Up to 4 redundant interconnect I/O fabrics (Ethernet, Fiber Channel, InfiniBand, iSCSI, SAS, etc.) supported simultaneously within the enclosure.

  • Choice of high-voltage single-phase AC, high-voltage three-phase, high-voltage single-phase AC, -48 VDC, or high-voltage DC power options for flexibility in connecting to data center power.

  • HP Thermal Logic technology to minimize power consumption and reduce cooling.

  •  A minimum of four active cool 200 HP hot-plug fans. For additional capacity, redundancy and improved power consumption and acoustics, Active Cool 200 Fan kits can be added for a maximum of 10 fans.

  • Redundant hot-plug cooling, redundant hot-plug power supplies, redundant connections, redundant interconnect modules, and optional redundant BladeSystem onboard administrator management module.

Benefits
  • With local and remote hardware management built into the entire solution, a complete cabinet can be managed as easily as a server.

  • Network management and interconnects extend scalability beyond a single cabinet, allowing resources to be pooled and shared across multiple cabinets.

  • Accommodates multiple server and network designs in one cabinet.

  • Lower power consumption compared to rack-mounted servers.

  • Lower costs per server compared to rack-mounted servers.

  • Lower airflow requirements compared to rack-mounted servers.

  • Reduced and simplified cabling compared to rack-mounted servers.

  • Investment protection with support for G1 to Gen9 server blades.

Onboard administrator management of the blade system
  • Robust configuration and control of multiple cabinets.

  • Reports asset and inventory information for devices in the enclosure.

  • Reports thermal and energy information, including real-time real-time energy usage by server and perenclosure.

  • Front-mount Insight Display for easy management in the data center.

  • Integrated access to all Integrated Lights-Out (iLO) blade servers from a single cable.

  • Provides integrated access to interconnect bay device management ports from a single integrated BladeSystem administrator cable.

  • Single sign-on capability for all cabinet devices.

  • Role-based security locally and/or with LDAP directory services.

  • Provides a wizard-based initial setup process for easy setup.

HPE Blade Systemc-Class c3000 Enclosure
For users who need a smaller blade system, the HPE BladeSystem c-Class c3000 Enclosure is the perfect solution. Supporting up to 8 blades and 4 interconnects, the c3000 enclosure offers an ideal solution for small and medium businesses and remote locations.
HPE ProLiant and integrity serverblades
  • Delivering best-in-class performance, choice and reliability on Intel Xeon and Intel Itanium processors for Windows, Linux, Solaris, OpenVMS or HP-UX-based servers; HPE's server blade portfolio supports a variety of application requirements for scale-up architectures.

  • Hewlett Packard Enterprise offers one-, two-, four- or eight-processor server blades with the widest range of performance and form factors.

HPE D2200sb Storage Blade
  • The D2220sb Storage Blade provides direct-attached storage for c-Class Gen8 server blades with support for up to twelve SAS or SATA Midline Small Form Factor (SFF) hot plug hard disk drives or SAS / SATA SSDs.

  • The chassis back panel provides a PCI express connection to an adjacent C-Class server blade and allows access to high-performance storage without any additional cables.

  • The D2220sb Storage Blade features an integrated Smart Array P420i controller with 2GB Flash-Backed Write Cache (FBWC) for increased performance and data protection. Up to eight D2220sb storage devices can be supported in a single BladeSystem c7000 Enclosure for up to 115,2TB of capacity.

HPE ultrium tape blades 1
  • Tape blades are ideal for HP BladeSystem c-Class users who need a data protection solution but are not connected to a storage area network (SAN).

  • They provide direct-attached data protection for the adjacent server and network backup protection for all other data within the enclosure. HP Tape Blades are the industry's first bladed tape drives and are designed exclusively for BladeSystem c-Class enclosures.

dynamic power limit
  • HPE Dynamic Power Cap is the industry's first power capping solution that allows the user to recover trapped power and cooling capacity without putting electrical infrastructure or server performance at risk.

  • The dynamic chassis power cap will be shared among all installed devices and individual server limits will change to match the server load. This will optimize the performance of the servers, ensuring that the cabinet stays below the maximum value.

Rack airflow requirements
10000 G2 series rack cabinets
The growing power of new high-performance processor technology requires greater cooling efficiency for rack-mounted servers. The G2 10000 series racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
Factory Express Portfolio for Servers and Storage
HPE Factory Express provides configuration, customization, integration and deployment services for HP servers and storage products. Users can choose how their factory solutions are built, tested, integrated, shipped and implemented.
HPE Simple Configurator
  • SCE is a self-service tool geared towards helping salespeople and non-technicians provide users with initial setups in 3-5 minutes. Submit configuration for configuration help or use in existing ordering processes.

  • If user needs rack configuration Custom or configuration for products not available in the SCE, contact your HPE User Business Center or an authorized partner for assistance.

HPE Energy Consultant
  • The HPE Power Advisor is a tool provided by Hewlett-Packard Enterprise to assist in estimating power consumption and proper selection of components, including system-level, rack- and multi-rack power supplies.

  • A variety of additional features are also provided, including a condensed bill of materials, a ship owner's cost calculator, and an energy report. HPE Power Advisor allows you to combine rack, tower, blade and other products in a single environment.

Physical Specifications

Environmental Specifications

Specifications
Overview
operating temperature 1
10° to 35°C (50° to 95°F)
Out of operation temperature
-30°C to 60°C (-22°F to 140°F)
operational relative humidity 1
10% to 90% non-condensing
Non-operating operational moisture
5% to 95% non-condensing
acoustic noise 2
Listed are the declared A-weighted sound power levels (LWAd) and the declared A-weighted sound pressure levels (LpAm) of the average spectator position when the product is operating in a 23°C environment. in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109)
Idle
LWAd
7,1 Bells
LpAm
54 dBA
Operational
LWAd
7,2 Bells
LpAm
54 dBA

NOTE: 1. The operating temperature has an altitude reduction of 1°C (1,8°F) per 304,8 m (1.000 ft). No direct sunlight. The upper operating limit is 3.048 m (10.000 ft) or 70 Kpa / 10,1 psia. The non-operating upper limit is 9.144 m (30.000 ft) or 30,3 Kpa / 4,4 psia. The maximum storage humidity of 95% is based on a maximum temperature of 45°C (113°F). The maximum storage altitude is 70 Kpa.

2. Listed are the declared A-weighted sound power levels (LWAd) and the A-weighted sound pressure levels (LpAm) of the declared mean observer position when the product is operating in a 23°C (73,4°F) environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Power Specifications

Specifications
Overview
Single Phase AC Power Input Module
Intelligent single-phase AC power input module 
power connection 1
6 blue power connectors IEC-320 C20
Rated input voltage
200 to 220V ac
Nominal input frequency
50 to 60 Hz
Number of supported power supplies
  • Minimum: One (1)

  • Maximum: Six (6)

2250 W power supply
Maximum output (per power supply): 2250 W
Maximum output (total for six power supplies): 13.050 W
Maximum input current (per power supply)
  • 13,1 A at 200 V ac

  • 12,6 A at 208 V ac

  • 11,9 A at 220 V ac

Maximum input power (per power supply): 2621 VA
2400 W gold power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.210 W
Maximum input current (per power supply)
  • 13,9 A at 200 V ac

  • 13,3 A at 208 V ac

  • 12,6 A at 220 V ac

Maximum input power (per power supply): 2780 VA
2400 W platinum power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.210 W
Maximum input current (per power supply)
  • 13,2 A at 200 V ac

  • 12,7 A at 208 V ac

  • 12,2 A at 220 V ac

Maximum input power (per power supply): 2640 VA
2650 W platinum power supply
Maximum output (per power supply): 2650 W
Maximum output (total for six power supplies): 15.370 W
Maximum input current (per power supply)
  • 14,4 A at 200 V ac

  • 13,8 A at 208 V ac

  • 13,1 A at 220 V ac

  • Maximum input power (per power supply): 2880 VA

Three-phase AC NA / JPN power input module
power connection
Two 3,05 m (10 ft) power cables with NEMA L15-30p connectors
Rated input voltage
  • 200 to 208 VAC line-to-line

  • three-phase delta

Nominal input frequency
50 to 60 Hz
Number of supported power supplies
  • Minimum: three (3)

  • Maximum: Six (6)

2250 W power supply
Maximum output (per power supply): 2250 W
Maximum output (total for six power supplies): 13.050 W
Maximum input current per line cable
  • 22,8 A at 200 V ac

  • 21,8 A at 208 V ac

Maximum input power per line cable: 7863 VA
2400 W gold power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.210W
Maximum input current per line cable
  • 24,2 A at 200 V ac

  • 23. 2 A at 208 V ac

Maximum input power per line cable: 8352 VA
2400 W platinum power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.210 W
Maximum input current per line cable
  • 22,9 A at 200 V ac

  • 22 A at 208 V ac

Maximum input power per line cable: 7920 VA
2650 W platinum power supply
Maximum output (per power supply): 2650 W
Maximum output (total for six power supplies): 15.370 W
Maximum input current per line cable
  • 25 A at 200 V ac

  • 24 A at 208 V ac

Maximum input power per line cable: 8640 VA
International three-phase AC power input module
power connection
Two 3,05 m (10 ft) power cables with IEC-309 220/380 V – 240/415 V connectors, 5 pins, 6h, 16A
Rated input voltage
  • 380 to 415 VAC line-to-line

  • 220 to 240 V AC line to neutral 2

  • 3-Phase WYE

Nominal input frequency
50 to 60 Hz
Number of supported power supplies
  • Minimum: three (3)

  • Maximum: Six (6)

2250 W power supply
Maximum output (per power supply): 2250 W
Maximum output (total for six power supplies): 13.050 W
Maximum input current per line cable:
  • 11,9 A at 220/380 V ac

  • 10,9 A at 240/415 V ac

Maximum input power per line cable: 7854 VA
2400 W gold power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.210 W
Maximum input current per line cable:
  • 12,6 A at 220/380 V ac

  • 11,5 A at 240/415 V ac

Maximum input power per line cable: 8316 VA
2400 W platinum power supply
Maximum output (per power supply): 2.450 W
Maximum output (total for six power supplies): 14.700 W
Maximum input current per line cable:
  • 12,2 A at 220/380 V ac

  • 11,2 A at 240/415 V ac

Maximum input power per line cable: 8064 VA
2650 W platinum power supply
Maximum output (per power supply): 2650 W
Maximum output (total for six power supplies): 15.370 W
Maximum input current per line cable:
  • 13,1 A at 220/380 V ac

  • 12 A at 240/415 V ac

Maximum input power per line cable: 8646 VA
-48 VDC Power Input Module
power connection
  • Terminal terminal: 45DG 4AWG 1/4 2H

  • two hole handle

  • 45 degree curvature

  • Pin hole size of 6,4 mm (0,25 in.)

  • 16 mm (0,63 in.) hole spacing

Rated input voltage
40 to 60 V dc
Number of supported power supplies
  • Minimum: One (1)

  • Maximum: Six (6)

2250 W -48 V dc power supply
Maximum output (per power supply): 2250 W
Maximum output (total for six power supplies): 13.050 W
Maximum input current (per power supply): 75 A
2650 W -48 V dc power supply
Maximum input power per source: 2700 W
Maximum output (per power supply): 2650 W
Maximum output (total for six power supplies): 15.370 W
Maximum input current (per power supply): 73A
Maximum input power per source: 2892 W
High Voltage Power Input Module
power connection
6x Saf-D-Grid APP receptacle connectors 3
Rated input voltage
277V ac, 380V dc
Nominal input frequency
50 to 60 Hz (AC), N / A (DC)
Number of supported power supplies
  • Minimum: One (1)

  • Maximum: Six (6)

2650 W universal power supply
Maximum output (per power supply): 2650 W
Maximum output (total for six power supplies) 15.370 W
Maximum input current (per power supply):
  • 10,5 A at 277 V ac
  • 7,6 A at 380 VDC

NOTE: 1. Blue power connectors indicate the capability of HPE Power Discovery Services. HPE Power Discovery Services are enabled when used with an intelligent power distribution unit (iPDU), iPDU cables, and a platinum power supply kit. One 250 m WW 19 W C20-C2,0 power cable is included per power supply. iPDU power cables are ordered separately.

2. 220 to 240V AC line-to-neutral rating. The cabinet will not operate at higher line-to-line voltage with the star wall plug configuration. This power input module is configured to supply 220 to 240 VAC to the power supplies.

3. Power cables with APP Saf-D-Grid connectors are ordered separately.

Some segments of the economy that we help

Some segments of the economy that we help

 

Third party maintenance for HPE End-of-Life (EOL) and HPE End-of-Service-Life (EOSL)

A DC Parts made an analysis on more than 250 customer contracts that use storage, servers, networks and tapes and showed us that 40-60% of the equipment of these customers operate beyond the end dates of support.

There are simple options for you to reduce your expenses and feel more confident about your IT infrastructure. When you choose a custom solution to extend the life of your IT equipment, you can make big savings.

How can we help:

We offer our customers a unique assessment to help analyze their OEM support contracts and understand exactly which devices can be supported in the most affordable way, without compromising their performance.

HPE Blade Leases

A DC Parts provides HPE server rentals for a convenient and affordable solution to a range of data center issues such as seasonal spikes and data center relocation. We work to match the right approach with the right equipment to properly meet your customized need for HPE Storage and Blade leases. With a highly trained team of certified engineers ready to solve any problems, DC Parts is uniquely qualified to serve you. If you would like to speak with a representative about leasing HPE machines, please contact us.

HPE Blade Support

Support services DC Parts support HPE appliances. We work to match the right approach with the right equipment to meet your HPE equipment support needs. With a highly trained team of certified engineers ready to resolve any issues with HPE equipment, DC Parts is uniquely qualified to serve you. If you would like to speak with a representative about purchasing HPE Equipment Support, please contact us. THE DC Parts helps companies of all sizes better manage their IT data centers by providing third-party support services to leading equipment manufacturers, including: IBM, HPE, DELL EMC, NETAPP and much more. With support DC Parts, we manage all your hardware, between the manufacturers through a link. Support from DC Parts offers flexible service level agreements, certified engineering support teams and dedicated customer service representatives. Extend the life and value of your IT assets. contact support DC Parts immediately.

HPE - Hewlett Packard Enterprise

HPE ProLiant BLADE Servers

Let's talk?

We will contact you as soon as possible